Self-Contained Systems
Self-contained units place all refrigeration cycle components in a single enclosure. Indoor models exhaust hot air through ducts or drop ceilings, while roof-top systems sit outside, saving space in the IT hall.
These systems suit smaller environments or facilities where fast deployment and minimal installation complexity are priorities. Advanced Power has delivered such solutions for education, healthcare, and laboratory clients where speed and budget were key.
Economiser-Based Cooling
Direct Fresh Air Cooling
Direct systems draw filtered outside air into the data centre when outdoor conditions are suitable. Often combined with evaporative cooling, they can cut energy use dramatically in dry climates.
Risks include: increased humidity and the introduction of fine particulates.
Indirect Air Cooling
Indirect systems keep indoor and outdoor air streams separate, transferring heat through air-to-air exchangers. This avoids contamination risks while still capturing the efficiency of outside conditions.
Both approaches can reduce cooling energy use by up to 75 percent in favourable climates. Advanced Power works with clients to assess whether their geography and operational profile make economiser modes viable.
Key Considerations for Choosing a System
Selecting the right cooling architecture is not about finding the “best” method overall but rather the best fit for specific requirements. Factors include:
- Uptime needs: higher criticality requires more resilient systems
- Power density: higher rack loads favour advanced options such as pumped refrigerant
- Climate: economisers excel in mild or dry regions
- Existing infrastructure: integration with building chillers or cooling towers may shape choices
- Budget and lifecycle costs: balancing capital and operational expenditure
Advanced Power provides consultancy to align these technical and financial factors, ensuring organisations avoid both under- and over-engineering their cooling systems.
There is no universal cooling solution for data centres. Each of the 13 heat removal methods has advantages and compromises that suit particular contexts. What is clear is that cooling is not simply an engineering afterthought but a strategic enabler of uptime, efficiency, and sustainability.
By developing a solid understanding of these technologies, IT leaders can engage confidently with facilities teams and make informed choices. With decades of experience, Advanced Power is ideally placed to help organisations evaluate, design, and deliver cooling strategies tailored to their operational goals.